CADDX NX 8 PROGRAMMING PDF

Download the Interlogix Networx (NX4, NX6, NX8, NX8E) Quickstart Guide HERE Programming Code = Master User Code= Program Mode= *8 +. The NX-8E NetworX from Caddx represents a new approach to the design of security systems. The NX-8E is probably the most flexible, durable, and. OFF I_ OFF_I 7 Test Reports Disabled. OFF I_ OFF_I 8 Program, Download & Log Full Disabled. Events to Report Phone 2 Second segment (Toggle On/Off then.

Author: Dogul Bazilkree
Country: Thailand
Language: English (Spanish)
Genre: Science
Published (Last): 28 January 2013
Pages: 339
PDF File Size: 5.26 Mb
ePub File Size: 10.48 Mb
ISBN: 957-9-67822-427-8
Downloads: 96797
Price: Free* [*Free Regsitration Required]
Uploader: JoJodal

Just thought I would make note of this. Somehow my baud rate was set to for my serial connection on Vera and when I went back through all my settings I noticed that this post indicated my baud rate should be set to option 4 31, I don’t think the baud rate matters as long as they match on the panel and vera side.

But is not a valid option according to the documentation in my panel. March 30, After entering, for exampleyou are greeted with a series of “Segments” The asterisk also takes you from segment to segment.

  BILL DUDNEY PDF

Check out our YouTube training videos. Segment 1, Segment 2 etc Home Help Search Login Register.

GE NX-1308E – Caddx 8 Zone LED Keypad Installation Manual: Nx-8 Programming Worksheets

For Locationenter ” “. Please login or register.

Took a look this morning as I could not get it to communicate and checked what I had my panel set at and it was indeed 4. Some locations have only one segment and others have several. I had an issue where my panel became disconnected from my Vera unit tends to happen when my lights go off, haven’t figured it out yet and I have to reboot the alarm system and reload Luup engine to fix it.

NX-8E panel programming details

Here are the steps and location entries you must make to program the alarm for Vera plugin control of the alarm system: Smart Home, made easy. Each segment has up to 8 data positions 1 2 3 4 5 6 7 8 which are either turned on you see the number displayed on the screen or OFF the individual number is NOT displayed. Did you miss your activation email?

  DERECHO FISCAL AUTOR ADOLFO ARRIOJA VIZCAINO PDF

You must get this “program” code to continue or cadvx the alarm company to program the following! I looked at the book and option 4 is 38, There was no corresponding value in Vera for that baud proggramming so I left it at The factory cxddx program code is “” but most alarm companies change the program code and are reluctant to give it out Location Data to be entered: Since I don’t dabble in this frequently this threw me for a loop so I thought I would post the correct value in case anyone else has this problem.

Once I set my baud rate in Vera to match it worked. The settings below show how to program the NX8-e directly from the alarm lcd panel: