AS NZS 3013 PDF

AS/NZS – Classification of the Fire and Mechanical Performance of Wiring System Elements This test is conducted in three parts: First Test. Download scientific diagram | Standard Time-Temperature Curve for AS/NZS from publication: CERAMIFYING INSULATION MATERIALS FOR FIRE. Austest Laboratories is pleased to announce further expansion of its capabilities to include mechanical testing of cables and wiring elements in.

Author: Yojora Samule
Country: Bosnia & Herzegovina
Language: English (Spanish)
Genre: Love
Published (Last): 10 April 2006
Pages: 413
PDF File Size: 8.73 Mb
ePub File Size: 11.25 Mb
ISBN: 636-3-18982-379-2
Downloads: 77290
Price: Free* [*Free Regsitration Required]
Uploader: Akinokazahn

Training Courses Voltimum webinars Voltimum e-Training. The cable nzw deemed to have passed when the specimen has been exposed to the test for the appropriate minimum time requested by the submitter without a failure. This document may make references to other documents. Prysmian explains fire ratings for cable. As tough 313 they get Nexans Olex Handbook. After a further 15 minutes the power is disconnected.

Within the context of these generic descriptions there is a myriad of performance tests in use around the world with which to qualify a cable to such requirements.

AS/NZS 3013:2005

The cable is deemed to have passed when it has been exposed to the specified level of impact energy without failure. This test is carried 33013 in a 3m cubed enclosure where a cable sample is subjected to fire. The smoke emission and density are measured by alight beam emitted across the inside of the enclosure to a photocell, measuring the amount of luminous transmission received. This level of compliance can be met by most Australian fire rated power and control cables using standard constructional parameters from the relevant build standard s.

  AVUSTUSHAKEMUS RAKENNUSPERINNN HOITOON PDF

All referenced documents are displayed below. The cable is deemed to have achieved the desired degree of protection when aw has been exposed to the fire test for the appropriate time and has sustained the effects of the water spray. Level of circuit integrity in fire condition.

AS/NZS – Classification of the Fire and Mechanical Performance of Wiring Sy

Mechanical Test Method Impact test: May 03, Other people who purchased this product also bought Please Login or Register. The impactor which is set at the prescribed drop height, is dropped 3 times onto the specimen.

Follow these links to find other Standards similar to the one you are viewing. A wedge shaped indentor is forced against the cable specimen and loaded until it cuts through the insulation in order to determine the ability of nza cable to nxs cutting action. After removal of the flame, the cables are wiped clean and the charring should not have exceeded 2.

International Classification for Standards ICS is an international classification system for technical standards. Water spray test applied. Click Buy for Online Library subscription.

Cable Fire Ratings and What they Mean

A rating that defines the performance of a Wiring System. Webinar Presentation on Safely protecting the electric A Title And here’s some amazing content. Please login or register. The criteria of this test states that the weighted pH value should not be less than 4. To pass the requirements of this test, the cable must remain operational both during the 90 minute exposure and the 15 minute cooling period.

  LES BASES DU FROID FRANCIS CABEZA PDF

30013

Cable Fire Ratings and What they Mean | Voltimum

It is designed to cover every economic sector and virtually every activity of the humankind where technical standards may be used. In the main, these standards are referenced in relation to installations where international cable build standards such as IEC are being considered and assessment of their suitability to the building code of Australia lies with the specifying engineer.

References This document may make references to other documents. Ask an Expert Trade Talk. Water Test Method After the cable specimen has passed the fire test, it is removed from the furnace and exposed to a water spray for 3 minutes. Intended for reference in other Standards which specify wiring systems with a degree of resistance to damage from fire or mechanical impact.

The cable is deemed to have passed when it has been exposed to the specified level of cutting force without failure.